Bidirectional / Positional Clearance Rules

Enable clearance rules that are orientation-agnostic (apply regardless of which attachment is above or below) and optionally allow different minimum clearances depending on the relative position. Current rules require an upper-attachment → lower-a...
3 months ago in SPIDAcalc 0 Needs review

Configure clearance by WEP type

Request to update the clearances configuration to allow for setting the WEP type(s) to which a midspan clearance should apply. This would allow creating reduced clearance tables for services to buildings as described in NESC 2023, Table 232-1, Foo...
3 months ago in SPIDAcalc 0 Needs review

3PH Poletop Extension Modeling

Currently Spida only allows for single phase poletop extension modeling, but there are materials available on the market, such as the attach Pupi Poletop Extensions, that can be used to model different phase configurations. The addition of the abi...
about 1 month ago in SPIDAcalc 0 Needs review

Add support for Equipment Classes to Clearances Configuration

There are multiple use cases for Equipment classes. Grounded/Ungrounded Classes This would allow clearance reporting to easily identify different clearance requirements based on the status of the equipment's grounding. Communication/Utility ...
3 months ago in SPIDAcalc 0 Needs review

Add support for Component Groups of Component Groups

There are many NESC 2023 classifications that are grouped differently depending on the rule. For example, Table 232-1 combines the following in the first column: Insulated Communication Conductors And Cable Messengers Overhead Shield/Surge-P...
4 months ago in SPIDAcalc 0 Needs review

Add component "Grounded" property

Add a check box property to wires and equipment to identify them as grounded. Allow this property to be used in the creation of Component Groups for clearance analysis.
4 months ago in SPIDAcalc 0 Needs review

Add wire voltage property

Add a wire property for voltage. Allow these to be defined in the client file and used in the creation of Component Groups.
4 months ago in SPIDAcalc 0 Needs review

Add support for wire phase label

Add support for applying a phase label to a wire that applies throughout the connected length of wire. This is mostly for primary phasing. Allow these to be customized in the client file. Examples include: A, B, C Left, Center, Right Road, Center,...
4 months ago in SPIDAcalc 0 Needs review

Get the possibility to attach equipment on crossarm

To being able to have a more precise pole look, some equipment are attached on crossarm.
about 1 year ago in SPIDAcalc 0 Needs review

Support Assemblies: preselect features included in support assembly prior to placement

With framing assemblies, the user can select the type of wires to be used in the assembly prior to placing. Support assemblies allows us to create common guying assemblies (such as 2 guys to 1 anchor, 2 guys to 2 anchors, and 4 guys to 4 anchors f...
7 months ago in SPIDAcalc 0 Needs review