Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 35 of 35

Multi selecting poles in the lead list

When working on large numbers of poles, it's useful to separate them into categories such as Telco-only, Power-only, Joint Use, etc for easier report export. But when moving poles between leads you can only select one at a time and the list doesnt...
about 1 month ago in SPIDAcalc 2 Needs review

Searchable remarks

I would like to request a search feature that would allow me to pull all permits within a workflow that have comments left in the remarks section. With admin rights I receive all emails and when a customer leaves a remark I lose the associated ema...
8 days ago in SPIDAstudio 0 Needs review

Configure clearance by WEP type

Request to update the clearances configuration to allow for setting the WEP type(s) to which a midspan clearance should apply. This would allow creating reduced clearance tables for services to buildings as described in NESC 2023, Table 232-1, Foo...
19 days ago in SPIDAcalc 0 Needs review

Add support for Equipment Classes to Clearances Configuration

There are multiple use cases for Equipment classes. Grounded/Ungrounded Classes This would allow clearance reporting to easily identify different clearance requirements based on the status of the equipment's grounding. Communication/Utility ...
23 days ago in SPIDAcalc 0 Needs review

Bidirectional / Positional Clearance Rules

Enable clearance rules that are orientation-agnostic (apply regardless of which attachment is above or below) and optionally allow different minimum clearances depending on the relative position. Current rules require an upper-attachment → lower-a...
about 1 month ago in SPIDAcalc 0 Needs review

Add support for Component Groups of Component Groups

There are many NESC 2023 classifications that are grouped differently depending on the rule. For example, Table 232-1 combines the following in the first column: Insulated Communication Conductors And Cable Messengers Overhead Shield/Surge-P...
about 2 months ago in SPIDAcalc 0 Needs review

Add component "Grounded" property

Add a check box property to wires and equipment to identify them as grounded. Allow this property to be used in the creation of Component Groups for clearance analysis.
about 2 months ago in SPIDAcalc 0 Needs review

Add wire voltage property

Add a wire property for voltage. Allow these to be defined in the client file and used in the creation of Component Groups.
about 2 months ago in SPIDAcalc 0 Needs review

Add support for wire phase label

Add support for applying a phase label to a wire that applies throughout the connected length of wire. This is mostly for primary phasing. Allow these to be customized in the client file. Examples include: A, B, C Left, Center, Right Road, Center,...
about 2 months ago in SPIDAcalc 0 Needs review

SPIDACalc 24.1 Project Details Report Bookmarks

I noticed that for the update from 24.0 to 24.1, the Project Details Report PDF no longer exports with the ability to navigate in Bluebeam with bookmarks- this was very handy for the 24.0 version.
about 1 year ago in SPIDAcalc 2 Needs review