Add support for Component Groups of Component Groups

There are many NESC 2023 classifications that are grouped differently depending on the rule. For example, Table 232-1 combines the following in the first column: Insulated Communication Conductors And Cable Messengers Overhead Shield/Surge-P...
11 months ago in SPIDAcalc 0 Future consideration

Add support for wire phase label

Add support for applying a phase label to a wire that applies throughout the connected length of wire. This is mostly for primary phasing. Allow these to be customized in the client file. Examples include: A, B, C Left, Center, Right Road, Center,...
11 months ago in SPIDAcalc 0 Future consideration

Batch Customizable Load Case & Clearance Case Entry (Instead of Pole by Pole)

I would like to suggest a easier way to set different wind load cases and/or clearances cases for different poles in the same project, without the need to go pole by pole to change wind values. Existing poles we use local wind, and pole replacemen...
9 months ago in SPIDAcalc 0 Planned

Update default Clearances icon in Design Status for clarity

In Design Status, update the default Clearances icon to something other than a green check mark, which makes it appear that it is passing clearance requirements. Instead, do sometihng like the Analysis icon where if there are no results, it shows ...
almost 2 years ago in SPIDAcalc 0 Planned

Get the possibility to attach equipment on crossarm

To being able to have a more precise pole look, some equipment are attached on crossarm.
over 1 year ago in SPIDAcalc 0 Future consideration

Extend SPIDAcalc API

Update the SPIDAcalc API to support: Reading project, form, lead, location, design, etc. properties Updating project, form, lead, location, design, etc. properties Getting the currently selected project, lead, location, or design Adding leads, loc...
over 1 year ago in SPIDAcalc 0 Needs review

Add support for Equipment Classes to Clearances Configuration

There are multiple use cases for Equipment classes. Grounded/Ungrounded Classes This would allow clearance reporting to easily identify different clearance requirements based on the status of the equipment's grounding. Communication/Utility ...
10 months ago in SPIDAcalc 0 Future consideration

Center pole top mounted equipment

Currently, equipment is modeled on the face of the pole. For pole top mounted equipment (such as antennas), this leads to the equipment being centered on the face of the pole rather than the center of the pole, which offsets the equipment's weight...
7 months ago in SPIDAcalc 0 Future consideration

Add component "Grounded" property

Add a check box property to wires and equipment to identify them as grounded. Allow this property to be used in the creation of Component Groups for clearance analysis.
11 months ago in SPIDAcalc 0 Future consideration

Add wire voltage property

Add a wire property for voltage. Allow these to be defined in the client file and used in the creation of Component Groups.
11 months ago in SPIDAcalc 0 Future consideration