Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 32

Multi selecting poles in the lead list

When working on large numbers of poles, it's useful to separate them into categories such as Telco-only, Power-only, Joint Use, etc for easier report export. But when moving poles between leads you can only select one at a time and the list doesnt...
7 days ago in SPIDAcalc 2 Needs review

Bidirectional / Positional Clearance Rules

Enable clearance rules that are orientation-agnostic (apply regardless of which attachment is above or below) and optionally allow different minimum clearances depending on the relative position. Current rules require an upper-attachment → lower-a...
6 days ago in SPIDAcalc 0 Needs review

Add support for Component Groups of Component Groups

There are many NESC 2023 classifications that are grouped differently depending on the rule. For example, Table 232-1 combines the following in the first column: Insulated Communication Conductors And Cable Messengers Overhead Shield/Surge-P...
28 days ago in SPIDAcalc 0 Needs review

Add component "Grounded" property

Add a check box property to wires and equipment to identify them as grounded. Allow this property to be used in the creation of Component Groups for clearance analysis.
28 days ago in SPIDAcalc 0 Needs review

Add wire voltage property

Add a wire property for voltage. Allow these to be defined in the client file and used in the creation of Component Groups.
28 days ago in SPIDAcalc 0 Needs review

Add support for wire phase label

Add support for applying a phase label to a wire that applies throughout the connected length of wire. This is mostly for primary phasing. Allow these to be customized in the client file. Examples include: A, B, C Left, Center, Right Road, Center,...
28 days ago in SPIDAcalc 0 Needs review

Adjust elevation beyond span

Currently in SpidaCalc you can adjust the elevation between two WEP or pole structures. However, setting an anchor on an incline or decline (relative to the base of the pole) has a notable impact on the corresponding guy strength and vertical load...
4 months ago in SPIDAcalc 0 Needs review

SPIDACalc 24.1 Project Details Report Bookmarks

I noticed that for the update from 24.0 to 24.1, the Project Details Report PDF no longer exports with the ability to navigate in Bluebeam with bookmarks- this was very handy for the 24.0 version.
about 1 year ago in SPIDAcalc 2 Needs review

Get the possibility to attach equipment on crossarm

To being able to have a more precise pole look, some equipment are attached on crossarm.
10 months ago in SPIDAcalc 0 Needs review

Extend SPIDAcalc API

Update the SPIDAcalc API to support: Reading project, form, lead, location, design, etc. properties Updating project, form, lead, location, design, etc. properties Getting the currently selected project, lead, location, or design Adding leads, loc...
6 months ago in SPIDAcalc 0 Needs review